MITSUBISHI HEAVY INDUSTRIES FDUA125AVNXVF Ducted Air Conditioner Single Phase / Inc RC-EX3 Back Lit Controller
|
SET |
FDUA125AVNXVF |
|
|
Indoor |
FDUA125VF |
|
|
Outdoor |
FDCA125VNX |
|
|
Power Supply |
1 Phase 220-240V 50Hz |
|
|
Capacity |
||
|
Cooling T1 |
kW |
12.5 (5.0-14.0) |
|
Heating H1 |
14.0 (4.0-17.0) |
|
|
Input |
||
|
Cooling T1 |
kW |
3.83 |
|
Heating H1 |
3.68 |
|
|
EER |
||
|
Cooling T1 |
|
3.26 |
|
COP |
||
|
Heating H1 |
|
3.80 |
|
Sound pressure level (JIS C9612) |
||
|
Indoor |
dB(A) |
P-Hi:45 Hi:43 Me:41 Lo:37 |
|
Outdoor |
48 |
|
|
Sound power level (JIS C9612) |
||
|
Outdoor |
dB(A) |
70 |
|
Airflow |
||
|
Indoor |
I/s |
P-Hi:717 Hi:650 Me:600 Lo:500 |
|
External static pressure |
Pa |
200 |
|
External dimensions (HxWxD) |
||
|
Indoor |
mm |
398 x 1150 x 650 |
|
Outdoor |
1300 x 970 x 370 |
|
|
Net weight |
||
|
Indoor |
Kg |
52 |
|
Outdoor |
105 |
|
|
Refrigerant piping |
||
|
Liquid line |
mm |
ᵩ9.52 |
|
Gas line |
ᵩ15.88 |
|
|
Connection method |
|
Flare Connection |
|
Refrigerant R410A |
||
|
Quantity |
Kg |
4.5 |
|
Pre charged to pipe length |
m |
30 |
|
Maximum Pipe Length |
m |
100 |
|
Supply air connection |
mm |
348 x 898 |
|
Return air connection |
mm |
|
|
Controller |
RC-E5; RC-EX1A or RCN-KIT3-E |
|
|
Safety pan |
UA-SP2-E (Optional) |
|